Systemy do elektroforezy

CESI 8000 Plus

CESI 8000 Plus – system elektroforezy kapilarnej z modułem do połączenia z MS do charakterystyki molekularnej białek, leków, peptydów i metabolitów

CESI 8000 Plus High Performance Separation- ESI Module
Includes CE separation module, OptiMS Sprayer cartridges, system controller pre-loaded with CESI 8000 software, portable height-adjustable lab bench designed for rapid change between LC and CESI front end.

Dimensions:
Height: 29.2 in (74.2 cm)
Door Open: 38.8 in (98.6 cm)
Width: 25 in (63.5 cm)
Depth: 28.4 in (72.1 cm)

Height Adjustable Portable Lab Bench with Memory Settings:
36 in x 30 in (91.4 cm x 76.2 cm)
Height adjustable from 27 in to 44 in (69 – 112 cm)

Weight (uncrated):
188 lbs (85.3 kg)

Electrical Requirements:
Voltage: 100 – 240 V; 50/60 Hz

Voltage Range:
1 to 30 kV programmable
at 0.1 kV increments

Current Range:
3 to 300 μA programmable
at 0.1 μA increments

Operating Environment Range:
15 – 30°C
20 – 60% relative humidity (non-condensing)

Sample Trays:
2 x 48 CESI vials / 0.3 mL microvials

Buffer Tray:
2 x 36 CESI vials

Sample Temperature Adjustment Range:
4 – 60°C

Capillary Temperature Adjustment Range:
15 – 30°C

Pressure Delivery Range:
-5 to +100 psi

Required Sample Volume:
5 μL when using NanoVials

Biologics Analysis by CESI-MS (Technical Notes/Posters/Webinars)

Link

Proteomics by CESI-MS (Technical Notes/Posters/Webinars)

Link

Metabolomics by CESI-MS (Technical Notes/Posters/Webinars)

Link

Analytical Chemistry (Technical Notes/Posters/Webinars)

Link

VIDEO

1. Introducing the CESI 8000: High Performance Separation – ESI Module

PA800 Plus

PA800 Plus – system elektroforezy kapilarnej dedykowany do analiz farmaceutycznych, białek, jonów, związków chiralnych

A66528 PA 800 Plus Pharmaceutical Analysis System Includes separation module with UV, photodiode array and LIF detection; system controller with PA 800 Plus software; system startup kit and reagents

A66527 PA 800S Plus Pharmaceutical Analysis System Includes separation module with photodiode array detection; system controller with PA 800 Plus software; system startup kit and reagents

Dimensions Height: 29.2 in (74.2 cm)
Door Open: 38.8 in (98.6 cm)
Width: 25 in (63.5 cm)
Depth: 28.4 in (72.1 cm)

Weight (uncrated) 188 lbs (85.3 kg) (includes photodiode array detection)

Electrical Requirements Voltage: 100 – 240 V; 50/60 Hz

Voltage Range 1 to 30 kV programmable at 0.1 kV increments

Current Range 3 to 300 μA programmable at 0.1 μA increments

Pressure Delivery Range -5 to +100 psi

Sample Temperature Control 4 – 60°C

Capillary Temperature Control 15 – 60°C

Sample Trays: 2 x 96-well plates 2 x 48 universal vials 2 x 48 0.2 mL microvials

Buffer Tray 2 x 36 universal vials

Detection Capability UV/Vis
200, 214, 254, 280 nm standard filter
190 – 600 nm (custom filter option)

Diode Array
190 – 600 nm (programmable)
0.5 – 32 Hz scan collection frequency (programmable)

Laser Induced Fluorescence (LIF)
300 – 700 nm excitation range
350 – 750 nm emission range
0 – 1000 RFU
Source Lasers with 3 mW Power Output 488 nm solid-state laser (included in A66528)

Link do strony producenta

C100HT BIOLOGICS ANALYZER

C100HT BIOLOGICS ANALYZER – system elektroforezy kapilarnej do szybkiego screening glikanów i optymalizacji hodowli komórkowych przy produkcji przeciwciał 

Broszura C100HT

C100HT – Workflow

C100HT – Repeatability

Link do strony producenta

P/ACE MDQ Plus

KLASYCZNA ELEKTROFOREZA KAPILARNA

P/ACE MDQ Plus – system klasycznej elektroforezy kapilarnej do analiz małych molekuł takich jak jony, związki chiralne, barwniki, cukry, aminokwasów, dodatków do żywności oraz wymiarowania DNA

System Specifications

Dimensions:
Height: 29.2 in (74.2 cm)
Door Open: 38.8 in (98.6 cm)
Width: 25 in (63.5 cm)
Depth: 28.4 in (72.1 cm)

Weight (uncrated):
188 lbs (85.3 kg) (includes UV/Vis Detector)

Electrical Requirements:
Voltage: 100 – 240 V; 50/60 Hz
Voltage Range: 1 to 30 kV programmable at 0.1 kV increments

Current Range:
3 to 300 μA programmable at 0.1 μA increments

Pressure Delivery Range:
-5 to +100 psi

Sample Temperature Control:
4 – 60°C

Capillary Temperature Control:
15 – 60°C

System Capacity

Sample Trays:
2 x 96-well plates
2 x 48 universal vials
2 x 48 0.3 ml vials or microfuge tubes

Buffer Tray:
2 x 36 universal vials

Detection Capability

UV/Vis (included)
200, 214, 254, 280 nm standard filter
190 – 600 nm (custom filter option

Diode Array (optional)
190 – 600 nm programmable
0.5 – 32 Hz scan collection frequency programmable

Laser Induced Fluorescence (LIF) (optional)
300 – 700 nm excitation range
350 – 750 nm emission range
0 – 1000 RFU

Broszura P/ACE MDQ Plus

Link do strony producenta